KOHLER Home Standby Generators & Automatic Backup Power

KOHLER home standby generator systems engineered for automatic backup of luxury residences and large estates. Regent5 coordinates generator sizing, natural-gas or propane supply, automatic transfer equipment, electrical service, load priorities, placement, commissioning and long-term support.

14RCA, 20RCA & 26RCA Air-⁠Cooled Home Generators

KOHLER’s current air-cooled range includes 14RCA, 20RCA and 26RCA models for residential standby power. We select generator size from measured and calculated loads, motor-start requirements, fuel availability and the circuits the homeowner expects to operate during an outage.

Learn More

Larger Liquid-Cooled Options for High-Demand Residences

The current KOHLER home generator catalog extends beyond air-cooled models into larger liquid-cooled systems such as 24RCLA, 38RCLC, 48RCLC and 60RCLB. These can serve properties with larger electrical services, multiple HVAC systems and substantial motor loads.

Learn More

Automatic Transfer Switching for Hands-⁠Off Outage Response

A properly designed standby system detects loss of utility power, starts the generator and transfers selected loads automatically. We coordinate the transfer switch with the service entrance, distribution panels, grounding, existing solar or batteries and the home’s backup priorities.

Learn More

Natural Gas, Propane & Fuel-⁠System Coordination

KOHLER residential standby models are available for natural gas and LPG. Generator performance depends on correct fuel pressure, pipe sizing, regulator capacity and expected load, so electrical and fuel planning must be coordinated early with the appropriate trades.

Learn More

Load Studies for HVAC, Pumps, EV Charging & Estate Systems

Generator sizing should account for more than square footage. We evaluate air-conditioning compressors, well and pool pumps, electric cooking, lighting control, security, network racks, elevators, gates and other loads that may need to operate during an outage.

Learn More

Generator + Battery + Solar Resilience Strategies

On advanced projects, a standby generator can be coordinated with battery storage, solar and managed loads to create multiple layers of backup. Regent5 designs the surrounding electrical architecture so each power source has a clear role during normal operation and grid failures.

Learn More

Get started.

Starting a project, or need help with planning one?

Share a few project details and the Regent5 team will follow up on goals, scope and next steps.

Prefer to talk? Call

(650) 242-5745

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Placement, Commissioning, Monitoring & Ongoing Service

Generator projects require coordinated clearances, airflow, exhaust, sound, fuel, electrical routing and service access. We commission transfer behavior, verify connected loads and integrate monitoring so the backup system can be maintained as part of the home’s critical infrastructure.

Get Service & Support

KOHLER Generator Design & Installation Capabilities

Regent5 engineers generator systems around the home’s actual electrical infrastructure, outage priorities and future energy strategy rather than selecting equipment by square footage alone.

14RCA Air-Cooled Systems

Compact residential standby generation for essential-load and smaller whole-home applications where the load study supports it.

20RCA Air-Cooled Systems

Popular residential standby platform for homes requiring more running capacity and strong motor-start performance.

26RCA High-Output Air-Cooled

26 kW LP / 24 kW natural-gas standby power for larger residential loads within an air-cooled platform.

Liquid-Cooled Estate Generators

Larger 24–60 kW-class residential options for high-demand properties and more complex electrical systems.

Automatic Transfer Switches

Automatic utility-loss detection and controlled transfer between grid and generator power.

Residential Load Calculations

Generator sizing around continuous load, motor starting, load diversity and the homeowner’s actual outage priorities.

Fuel-System Coordination

Natural-gas or propane requirements coordinated with generator output, pipe sizing and the project’s mechanical design.

Siting, Sound & Service Access

Equipment placement planned around clearances, airflow, exhaust, neighboring spaces, landscaping and maintenance access.

Battery & Solar Coordination

Generator integration within broader energy systems that may also include storage, PV, smart loads and upgraded electrical service.

Commissioning & Support

Transfer testing, connected-load verification, monitoring setup, documentation and ongoing electrical support.

Where we work.

KOHLER Home Standby Generator Design, Installation and Service

Regent5 designs, installs and supports KOHLER home standby generator systems across the San Francisco Bay Area and Northern California, including the Peninsula, San Francisco, the South Bay, the East Bay, Marin, Wine Country and Carmel and Monterey. Projects include custom homes, estates and multi-building properties, coordinated from the load study, fuel supply and transfer equipment through permitting, commissioning and long-term service.

KOHLER Home Generator FAQs

What KOHLER generator size is right for my home?

The correct size depends on which loads must operate during an outage, their running demand and their starting current. We perform a residential load study instead of sizing only from home square footage.

Can a KOHLER standby generator power an entire house?

Yes, when the generator and transfer architecture are sized for the home’s load. Large estates may require a larger liquid-cooled generator, load management or a defined set of backed-up circuits.

Do KOHLER home generators run on natural gas or propane?

Many KOHLER residential standby generators are designed for natural gas or LPG. The selected fuel affects available output and requires properly sized piping, regulators and fuel supply.

What does an automatic transfer switch do?

The transfer switch detects utility loss, isolates the appropriate electrical source and connects the home or selected circuits to generator power after the generator starts. It transfers back when utility service is restored.

How loud is a KOHLER standby generator?

Sound varies by model and operating condition. For example, KOHLER lists the 26RCA at 56 dB(A) during its weekly exercise mode and 67 dB(A) at full-speed operation, so placement should consider neighbors and occupied spaces.

Where should a standby generator be located?

Placement must account for manufacturer clearances, exhaust, openings into the building, fuel routing, electrical distance, drainage, landscaping, sound and local code. We coordinate these constraints before finalizing the location.